Home Products Circuit Breaker Low-voltage circuit-breaker HU Series High-Voltage Molded Case Circuit Breaker

HU Series High-Voltage Molded Case Circuit Breaker

The HU series is a high-voltage molded case circuit breaker (MCCB) for AC networks up to 1140V and 63–800A. With overload and short-circuit instantaneous protection, it distributes power and safeguards lines and power equipment against overload, short-circuit and other faults. Designed for new energy — wind and photovoltaic — applications, it features a novel design, compact size, high breaking capacity and modular internal accessories.
Send Inquiry

Overview

The HU series is a high-voltage molded case circuit breaker (MCCB) for AC networks up to 1140V and 63–800A. With overload and short-circuit instantaneous protection, it distributes power and safeguards lines and power equipment against overload, short-circuit and other faults. Designed for new energy — wind and photovoltaic — applications, it features a novel design, compact size, high breaking capacity and modular internal accessories.

Why Choose Us

✓ High voltage up to 1140V — covers 800/1000/1140V grids in ONE frame family
✓ Up to 50kA rated ultimate short-circuit breaking (Icu), Icu = Ics for reliable fault clearing
✓ Zero arcing distance (0 mm) — safer installation, no arc-chute clearance needed
✓ Modular accessories — shunt release, auxiliary, alarm, combined units share one footprint
✓ Isolation function (symbol —/—) + Category A, meets GB/T 14048.1/.2 (IEC 60947-1/-2)
✓ Wide ambient range -45°C to +70°C, altitude up to 2000m (derating above)

Key Features

Feature Description
Novel & Compact Design Newly engineered moulded case with optimised internal layout — smaller footprint than conventional HV MCCBs, easier panel integration.
High Breaking Capacity Rated ultimate short-circuit breaking capacity Icu up to 50kA (AC800V), with Icu = Ics across the range — no capacity derating after fault clearance.
Modular Accessories Internal accessories (shunt release, auxiliary contact, alarm contact and combinations) share a common mounting footprint and are field-configurable.
Isolation Function Built-in isolation function (symbol —/—), compliant with disconnector requirements per GB/T 14048.1 / IEC 60947-1.
Zero Arc Distance Arc-chute design achieves 0 mm arcing distance — improves cabinet layout safety and reduces installation clearance.
Wide Environmental Range Ambient -45°C to +70°C, altitude ≤2000m, pollution degree 3, installation category III — suited to harsh wind/solar sites.
Flexible Mounting Vertical or horizontal mounting; front-plate, rear and plug-in wiring options available.
Long Service Life Mechanical life 20,000 operations, electrical life 1,500 operations — low maintenance over the project lifetime.
Scope & Standards
Item Parameter
Rated circuit AC networks up to 1140V, rated current 63–800A
Protection Overload and short-circuit instantaneous protection
Poles 3P (three-pole)
Utilisation category Category A
Isolation Yes (symbol —/—)
Reference ambient +40°C
Standards GB/T 14048.1 Low-voltage switchgear and controlgear — Part 1: General rules
GB/T 14048.2 Low-voltage switchgear and controlgear — Part 2: Circuit-breakers
(equivalent to IEC 60947-1 / IEC 60947-2)
 Normal Service & Installation Conditions
Item Parameter
Altitude ≤ 2000 m
Ambient temperature -45°C to +70°C
Humidity At 20°C: 90%; at 40°C: ≤50%; higher humidity allowed at lower temperatures (condensation considered)
Pollution degree 3
Installation category III
Mounting magnetic field ≤ 5 × earth magnetic field in any direction
Medium Non-explosive, no corrosive gas or conductive dust
Mounting Horizontal or vertical; no significant shock/vibration; not in flammable/explosive locations
 Main Technical Data
Parameter Unit HU-250
AC800/1000/1140V
HU-315
AC1140V
HU-400
AC800/1000/1140V
HU-630/800
AC800/1000/1140V
Rated current In A 16,20,25,32,63,80,100,125,140,160,180,200,225,250 280,300,315 250,315,350,400 400,500,630 (HU-630); 630,700,800 (HU-800)
Rated operational voltage Ue V AC800 | AC1000 | AC1140 AC1140 AC800 | AC1000 | AC1140 AC800 | AC1000 | AC1140
Rated insulation voltage Ui V 1150 (AC800/1000); 1250 (AC1140) 1250 1250 1250
Rated impulse withstand Uimp kV 12 12 12 12
Breaking class — H (AC800) H (AC1140) — —
Icu (ultimate SC breaking) kA 50 | 50 | 20 25 | 15 | 20 50 | 20 | 15 50 | 20 | 15
Ics (service SC breaking) kA 35 | 50 | 15 20 | 15 | 15 37.5 | 15 | 15 37.5 | 15 | 15
Isolation — Yes Yes Yes Yes
Utilisation category — A A A A
Mechanical life operations 20,000 20,000 20,000 20,000
Electrical life operations 1,500 1,500 1,500 1,500
Arcing distance mm 0 0 0 0
Dimensions (breaker body) mm 200×107×138 200×107×138 257×150×156 270×182×158
Dimensions (with accessories) mm 280×107×138 280×107×138 307×150×156 320×182×158
Protection Characteristics
Circuit-breaker In 1.05In (cold) 1.3In (hot) Magnetic trip current
63A ≥1 h ≤1 h 10In ±20%
63 < In ≤ 800A ≥2 h ≤2 h 10In ±20%
Installation Dimensions ( mm)
Model A B C D E F G H I J Mounting holes
n-Φd
HU-250 30 30 30 30 188 13 80 280 94 53 2-Φ4.5
HU-315 30 30 30 30 188 13 80 280 94 53 2-Φ4.5
HU-400 30 30 30 30 153.5 13 50 307 118 53 2-Φ4.5
HU-630 30 30 30 30 185 13 50 320 118 60 2-Φ4.5
HU-800 30 30 30 30 185 13 50 320 118 60 2-Φ4.5

Note:At 1000V & 1140V: fit terminal covers on terminals 1/3/5, phase barriers on 2/4/6, and an insulating plate between breaker and metal mounting plate.

Related Products

Send Inquiry

产品询盘