Home Products Circuit Breaker Low-voltage circuit-breaker HKM7L Residual Current Operated Circuit Breaker

HKM7L Residual Current Operated Circuit Breaker

This product is suitable for low-voltage power grid systems with three-phase four-wire neutral point directly grounded (TT system). It protects lines and electrical equipment from grounding faults, overcurrent, short circuit, overvoltage, undervoltage, phase loss after power failure and automatic tripping. It also provides indirect contact protection against personal electric shock. Conforms to standards: IEC 60947-2:2019, Communication RS-485 interface
Send Inquiry

Product overview

This product is suitable for the low-voltage power grid system with three-phasefour-wire neutral point directly grounded (TT). It is used to protect the line orelectrical equipment from grounding fault, overcurrent, short circuit, overvoltage,undervoltage, automatic tripping and phase loss after power failure. It can alsoprovide indirect contact protection against personal electric shock.The product conforms to the standards: GB/T 14048 2, GB/T 32902, DL/T 20.Communication protocol for residual current circuit breaker.Note: This manual is applicable to both right N-type products and left N-typeproducts.

Key Highlights

Seven-fold intelligent protection: overload, short-circuit, residual current, overvoltage, undervoltage, phase loss & auto-reclosing

Triple residual-current detection: auto-tracking, sudden-change & special-wave identification

Real-time monitoring of 3-phase voltage, current & residual current with LCD wheel display

Auto-reclosing (20~60s adjustable) — intelligent power recovery after voltage normalises

Standard RS-485 + DL/T-20 communication, optional infrared for smart-grid remote O&M

Complies with State Grid Q/GDW1972 (distributed PV grid-tie) & Q/GDW11289 (lightning protection)

Ideal for distributed PV, rural low-voltage distribution, industrial & building smart distribution

Typical Applications

Three-phase four-wire TT low-voltage networks · Distributed PV grid-tie · Rural low-voltage distribution protection · Industrial/commercial smart distribution · Sites requiring RCD + smart communication

Product Features

Protection

Residual-current auto-tracking, sudden-change & special-wave detection; over/undervoltage & phase-loss protection; auto-reclosing after voltage recovery; electronic overload, instantaneous & short-delay short-circuit protection; zero-loss & power-failure trip protection.

Display

In closed state, automatically wheel-displays: rated residual operating current, rated current, current time, max leakage value & phase, 3-phase voltage & current parameters.

Setting & Query

Enable/disable residual-current alarm, auto-tracking, sudden-change, special-wave, auto-reclosing, over/undervoltage, phase loss, overload, zero-loss protection via keys or communication; query trip records, test records, total & locked trip counts.

Control

Field test-trip via [Test] key; remote reservation of open/close/test-trip/cancel; synchronous open/close via external interfaces.

Self-test

Three self-check functions: remote trial-trip, scheduled trial-trip & key trial-trip, plus voltage self-check closing.

Monitoring & Recording

Records residual current, 3-phase voltage & current daily max/min and time scale within 30 days (14 records); records parameters & time scale of nearly 10 trips.

Auxiliary

RS485 fully supports the forthcoming DL/T Residual Current Circuit Breaker Communication Protocol; meets Zhejiang Provincial specification and State Grid Q/GDW1972 & Q/GDW11289 enterprise standards.

Normal Operating Conditions

 Ambient temp. -5℃ ~ +40℃
Relative humidity When avg. min. temp. of wettest month ≤25℃, avg. max. relative humidity ≤90%; condensation considered
Altitude ≤ 2000m
Pollution degree Grade 3
Installation category III
External magnetic field ≤ 5× geomagnetic field in any direction

Product Parameters

Parameter 125A 250A 400A / 630A / 800A  Remarks
Inm / Frame rated current 125A 250A 400A / 630A / 800A —
In / Rated current (0.4~1)In Adjustable (0.4~1)In  Adjustable (0.4~1)In Adjustable Adjustable (0.4~1)In
Ue / Rated operating voltage AC400V AC400V AC400V —
Ui / Rated insulation voltage AC1000V AC1000V AC1000V —
 Uimp / Impulse withstand voltage 8000V 8000V 8000V —
Icu / Ultimate SC breaking cap. M:50kA / H:65kA M:50kA / H:65kA M:65kA / H:85kA M— Standard breaking capacity (standard type)
H— High breaking capacity (high interrupting type)
 Ics / Operating SC breaking cap. M:35kA / H:50kA M:35kA / H:50kA M:50kA / H:65kA —
Icw / Short-time withstand 5kA/1s 10kA/1s 10kA/1s —
 Ue / Auxiliary supply voltage AC400V AC400V AC400V —
Pole 4P  or 3P+N 4P  or3P+N 4P  or 3P+N 4P or 3P+N

Residual-current & Function Settings

Item Parameter Factory default Adjustable range Remarks
I△n / Rated residual operating current 300mA/500mA 300mA/500mA 10 sets of parameters are customizable (50~1000mA) 10 sets customisable
 Residual non-operating current I△no = 50% I△n — — I△no = 50% I△n
Limit non-driving time 0.06 s 0.06 s 3 groups customisable (0.06/0.2/0.3 ) 3 groups customisable
Delay reclosing time — — 20~60 s —
Motion characteristic  AC Type — — AC Type
Product use category  B Type — — B Type
Overvoltage protection 275V ± 5%(Self-tuning)  Factory default: disabled User-configurable,  User-configurable, set range 245–300V
Undervoltage protection 165V ± 5% (Self-tuning)  Factory default: disabled User-configurable, User-configurable, set range 140–200V

Product appearance and installation size

HKM7L Residual Current Operated Circuit Breaker detail

Frame L W H H1 a b D L1 L2 H2 e d
125A 185 122 120 64 164 60 6×φ4 167 7 26 30 —
125A 185 122 120 64 164 60 6×φ4 167 7 26 30 —
250A 220 122 121 64 200 60 6×φ4 202 7 26 30 —
400A 240 142 132 84 200 70 6×φ4 218 10 24 35 —
630A 335 196 177 99 273 96 6×φ6 305 12 36 48 —
630A 335 196 177 99 273 96 6×φ6 305 12 in:38/out:39 48 —
800A 335 240 179 108 271 116 6×φ6 300 in:20/out:18 in:38/out:32 58 —

Ordering Description:When ordering, specify: Model (HKM7L) + Frame current (125/250/400/630/800A) + Breaking class (M standard / H high-breaking) + Pole (4P or 3P+N) + Rated residual operating current (e.g. 300mA/500mA) + Optional functions (infrared, etc.). Example: HKM7L-400A/H/4P/300mA.

Related Products

Send Inquiry

产品询盘